Chemical Filters in Malaysia
A chemical filter uses activated carbon or other gas-phase media to remove gases, odours and airborne molecular contamination that particle filters cannot catch.

Chemical Filters range
Carbon and chemical media for gases, odours and airborne molecular contamination. Open any model for its details, or add it to your enquiry list.
Chemical Carbon Pleated Filter
Constructed with a beverage board and pleated media to provide maximum effective area. Carbon pleated filters remove a wide range of odours and common indoor air pollutants.
Specifications · PDFChemical Rigid Pleated Filter
The gas-phase rigid pleated filter ensures a higher effective active area per kg of media, resulting in a high spontaneity of reactions Gas-phase rigid pleated filters remove a wide range of odours and common indoor air pollutants.
Specifications · PDFChemical V-Bank MiniPleat Filter
Gas-phase V bank filter ensures a higher effective active area per kg of media, resulting in high spontaneity of reactions. Gas-phase V bank filters remove a wide range of odours and common indoor air pollutants.
Specifications
What is a chemical filter?
A chemical filter uses activated carbon or other gas-phase media to remove gases, odours and airborne molecular contamination that particle filters cannot catch.
- Where it is used
- Make-up and recirculation air in semiconductor plants, laboratories, airports and commercial buildings where odours or corrosive gases are a concern.
- Range
- Chemical Carbon Pleated Filter, Chemical Rigid Pleated Filter, Chemical V-Bank MiniPleat Filter
- Supplied by
- Vicfil Sdn. Bhd., Puchong, Selangor. Delivery across Malaysia.
Chemical Filters datasheets (PDF)
Chemical Filters specifications and details
Chemical Carbon Pleated Filter
- Constructed with a beverage board and pleated media to provide maximum effective area.
- Carbon pleated filters remove a wide range of odours and common indoor air pollutants.
Specifications
| Nominal size W x H x D (in) | Actual size W x H x D (mm) | Efficiency (EN779) | Air flow / initial resistance (CMH / Pa) |
|---|---|---|---|
| 12 x 24 x 2 | 289 x 594 x 44 | G4 | 1700 / 130 |
| 24 x 24 x 2 | 594 x 594 x 44 | G4 | 3400 / 130 |
| 12 x 24 x 4 | 289 x 594 x 95 | G4 | 1700 / 110 |
| 24 x 24 x 4 | 594 x 594 x 95 | G4 | 3400 / 110 |
Questions and answers
What are chemical (gas/vapour) filters?
Chemical filters usually activated carbon or chemisorption filters) Specifically engineered to remove gases, odours, and Volatile Organic Compounds (VOCs) from industrial exhaust or ventilation air streams
How do they work?
Activated carbon filters contain a lot of internal surfaces which can adsorb pollutants on its surface.
HEGA filters employ dense substrates in combination with activated carbon specifically engineered for gas and odour elimination
What Type Of Filters Are Usually Used For Chemicals?
They’re commonly employed in:
- Fume hoods (biotech, pharmaceutical, forensic labs) Air Science
- Industrial applications involving VOC/hazardous gas removal
What are the different types of activated carbon media?
- Granular activated carbon (GAC): for air, gas/vapour phase
- Extruded activated carbon (EAC) (low-pressure drop and robust) – ideal for gas phase
- Bead Activated Carbon(BAC): used in Fluidized-bed applications
How frequently should I remove chemical filters?
Typical replacement intervals:
- Every 6 months for particulate + carbon combination systems
- Use delta-p monitoring to show saturation.
Chemical Rigid Pleated Filter
- The gas-phase rigid pleated filter ensures a higher effective active area per kg of media, resulting in a high spontaneity of reactions
- Gas-phase rigid pleated filters remove a wide range of odours and common indoor air pollutants.
Specifications
| Nominal size W x H x D (in) | Actual size W x H x D (mm) | Air flow / initial resistance (CMH / Pa) |
|---|---|---|
| 12 x 24 x 12 | 289 x 594 x 292 | 1700 / 90 |
| 24 x 24 x 12 | 594 x 594 x 292 | 3400 / 90 |
- Data based on no header.
Chemical V-Bank MiniPleat Filter
- Gas-phase V bank filter ensures a higher effective active area per kg of media, resulting in high spontaneity of reactions.
- Gas-phase V bank filters remove a wide range of odours and common indoor air pollutants.
Specifications
| Nominal size W x H x D (in) | Actual size W x H x D (mm) | Air flow / initial resistance (CMH / Pa) |
|---|---|---|
| 24 x 12 x 12 | 594 x 289 x 292 | 1700 / 80 |
| 24 x 24 x 12 | 594 x 594 x 292 | 3400 / 80 |
- Actual size given does not include gasket.
Chemical Filters: common questions
What is a chemical filter?
A chemical filter uses activated carbon or other gas-phase media to remove gases, odours and airborne molecular contamination that particle filters cannot catch.
Which chemical filters models does Vicfil supply?
Vicfil supplies 3 models: Chemical Carbon Pleated Filter, Chemical Rigid Pleated Filter, Chemical V-Bank MiniPleat Filter.
Where is it used?
Make-up and recirculation air in semiconductor plants, laboratories, airports and commercial buildings where odours or corrosive gases are a concern.
Can it be customised?
Yes. Vicfil can customise the size, layout and options to your room and process. Send your requirements with the enquiry form.
Is there a datasheet I can download?
Yes. 2 PDF datasheets are available to download from this page: Carbon Pleated Filter, Carbon Rigid Pleated Filter.
How do I get a quotation?
Add the models you need to your enquiry list and send the enquiry form with your quantities. You can also WhatsApp +6012 272 3963 or email sales@vicfil.com.