HEPA & ULPA Filters in Malaysia

HEPA and ULPA filters are the final, high-efficiency stage of cleanroom filtration. HEPA is typically rated at least 99.97% at 0.3 µm and ULPA at least 99.999% at 0.12 µm, and the grade you fit sets the class your cleanroom can reach.

HEPA & ULPA Filters by Vicfil
Industrial Air Filters

HEPA / ULPA Filters range

Final-stage high-efficiency filters and ceiling modules that set your cleanroom class. Open any model for its details, or add it to your enquiry list.

8 models
  • MiniPleat Filter

    Filter uses a mini pleat glass fibre media with efficiencies from H13 to U15. The extended media surface combined with precisely controlled bead separator pleating creates low resistance to air flow and save energy consumption.

    Specifications · PDF
  • Permanent Ceiling Module

    Complete unit designed with a low pressure drop to save energy consumption and provide a longer service life. Designed for easy installation. Filter use glass fibre media which is a mini pleat type and aluminium separator type.

    Specifications · PDF
  • Permanent Ceiling Module RSC Type

    Complete unit designed with a low pressure drop to save energy consumption and provide a longer service life. Designed for easy installation. Filter use glass fibre media which is a mini pleat type. Casing are designed with a permanent knife edge for gasket and a Gel Seal type filter.

    Specifications
  • Disposable Ceiling Module

    Complete unit designed with a low pressure drop to save energy consumption and provide a longer service life. Designed for easy installation. Module use of glass fibre media which is a mini pleat type.

    Specifications · PDF
  • V-Bank MiniPleat Filter

    Extended media surface creates lower resistance to higher air flow which saves energy consumption. Large media area provides the filters with a longer serving life and higher dust holding capacity.

    Specifications
  • V-Bank Mini Pleat Filter (Box Type)

    Extended media surface creates lower resistance to higher air flow which saves energy consumption. Large media area provides the filters with a longer serving life and higher dust holding capacity.

    Specifications
  • Aluminium Separator Filter (High Air Capacity)

    The media pack consists of pleated micro glass paper media and corrugated aluminium separator which is sealed inside the metal frame forming a totally rigid filter assembly. Polyurethane sealant applies throughout all over the filter to prevent any possible leakage.

    Specifications
  • Aluminium Separator Filter (Std Air Capacity)

    The media pack consists of pleated micro glass paper media and corrugated aluminium separator which is sealed inside the metal frame forming a totally rigid filter assembly. Polyurethane sealant applies throughout all over the filter to prevent any possible leakage.

    Specifications

What are HEPA and ULPA filters?

HEPA and ULPA filters are the final, high-efficiency stage of cleanroom filtration. HEPA is typically rated at least 99.97% at 0.3 µm and ULPA at least 99.999% at 0.12 µm, and the grade you fit sets the class your cleanroom can reach.

Where it is used
Cleanroom ceilings, fan filter units, air handling units and clean equipment in semiconductor, pharmaceutical, hospital and laboratory facilities.
Range
MiniPleat Filter, Permanent Ceiling Module, Permanent Ceiling Module RSC Type, Disposable Ceiling Module, V-Bank MiniPleat Filter, V-Bank Mini Pleat Filter (Box Type), Aluminium Separator Filter (High Air Capacity), Aluminium Separator Filter (Std Air Capacity)
Supplied by
Vicfil Sdn. Bhd., Puchong, Selangor. Delivery across Malaysia.

HEPA / ULPA Filters specifications and details

MiniPleat Filter
  • Filter uses a mini pleat glass fibre media with efficiencies from H13 to U15.
  • The extended media surface combined with precisely controlled bead separator pleating creates low resistance to air flow and save energy consumption.

Specifications

Size and performance data
Nominal size W x H x D (in)Actual size W x H x D (mm)Efficiency (EN1822)Air flow / initial resistance (CMH / Pa)
12 x 24 x 2.3/4 / 3.1/8305 x 610 x 69 / 81H13300 / 110
24 x 24 x 2.3/4 / 3.1/8610 x 610 x 69 / 81H13600 / 110
45 x 21 x 2.3/4 / 3.1/81140 x 530 x 69 / 81H13960 / 110
48 x 24 x 2.3/4 / 3.1/81220 x 610 x 69 / 81H131200 / 110
12 x 24 x 2.3/4 / 3.1/8305 x 610 x 69 / 81H14300 / 125
24 x 24 x 2.3/4 / 3.1/8610 x 610 x 69 / 81H14600 / 125
45 x 21 x 2.3/4 / 3.1/81140 x 530 x 69 / 81H14960 / 125
48 x 24 x 2.3/4 / 3.1/81220 x 610 x 69 / 81H141200 / 125
12 x 24 x 2.3/4 / 3.1/8305 x 610 x 69 / 81U15300 / 145
24 x 24 x 2.3/4 / 3.1/8610 x 610 x 69 / 81U15600 / 145
45 x 21 x 2.3/4 / 3.1/81140 x 530 x 69 / 81U15960 / 145
48 x 24 x 2.3/4 / 3.1/81220 x 610 x 69 / 81U151200 / 145
  • Actual sizes are measured without gasket.
View the original specification image

Diagram

MiniPleat Filter diagram

Questions and answers

What are HEPA and ULPA filters, and what is the difference between them?

HEPA (High-Efficiency Particulate Air) filters and ULPA (Ultra-Low Penetration Air) filters are both high-efficiency filtration materials. HEPA filters can remove 99.97% of particles that are 0.3 microns in size, while ULPA filters can remove 99.999% of particles as small as 0.12 microns. ULPA filters offer a higher filtration efficiency than HEPA filters and are suitable for environments requiring even greater cleanliness.

What industries use HEPA/ULPA filters?

These filters are widely used in industries such as healthcare, pharmaceuticals, biotechnology, and electronics manufacturing, especially in environments that require extremely high levels of cleanliness, such as operating rooms, cleanrooms, and semiconductor manufacturing facilities.

How do I choose the right HEPA or ULPA filter for my needs?

Choosing the right filter depends on the required filtration efficiency, filter size, and the specific application. HEPA filters are suitable for general clean environments, while ULPA filters are used in places that demand higher cleanliness standards. It’s recommended to consult with a professional to select the most appropriate filter for your specific needs.

How often should HEPA/ULPA filters be replaced?

The replacement frequency of filters depends on the usage environment and the types of particles being filtered. In highly contaminated environments, filters may need to be replaced every six months to a year. Regular inspection and replacement based on the manufacturer’s recommendations are essential to maintain optimal filtration performance.

Can HEPA/ULPA filters remove all types of contaminants?

While HEPA and ULPA filters are highly effective at removing most particles like dust, bacteria, and pollen, they cannot filter gases or vapors. If gas pollutants need to be filtered, it is recommended to use additional filters, such as activated carbon filters.

Permanent Ceiling Module
  • Complete unit designed with a low pressure drop to save energy consumption and provide a longer service life.
  • Designed for easy installation. Filter use glass fibre media which is a mini pleat type and aluminium separator type.

Specifications

Size and performance data
Casing size W x H x D (in)Filter size W x H x D (mm)Efficiency (EN1822)Air flow / initial resistance (CMH / Pa)
600 x 600 x 200530 x 530 x 69H13450 / 110
1210 x 600 x 2001140 x 530 x 69H13960 / 110
600 x 600 x 280530 x 530 x 150H13630 / 249
1210 x 600 x 2801140 x 530 x 150H131350 / 249
600 x 600 x 430530 x 530 x 292H131260 / 249
1210 x 600 x 4301140 x 530 x 292H132700 / 249
  • Actual size given does not include gasket.
View the original specification image

Diagram

Permanent Ceiling Module diagram
Permanent Ceiling Module RSC Type
  • Complete unit designed with a low pressure drop to save energy consumption and provide a longer service life.
  • Designed for easy installation. Filter use glass fibre media which is a mini pleat type.
  • Casing are designed with a permanent knife edge for gasket and a Gel Seal type filter.

Specifications

Size and performance data
Casing size W x H x D (in)Filter size W x H x D (mm)Efficiency (EN1822)Air flow / initial resistance (CMH / Pa)
600 x 600 x 152568 x 568 x 69/81H13600 / 110
900 x 600 x 152868 x 568 x 69/81H13960 / 110
1210 x 600 x 1521178 x 568 x 69/81H131200 / 110
600 x 600 x 152568 x 568 x 69/81H14600 / 125
900 x 600 x 152868 x 568 x 69/81H14960 / 125
1210 x 600 x 1521178 x 568 x 69/81H141200 / 125
600 x 600 x 152568 x 568 x 69/81U15600 / 145
900 x 600 x 152868 x 568 x 69/81U15960 / 145
1210 x 600 x 1521178 x 568 x 69/81U151200 / 145
  • Actual size given does not include gasket.
View the original specification image

Diagram

Permanent Ceiling Module RSC Type diagram
Disposable Ceiling Module
  • Complete unit designed with a low pressure drop to save energy consumption and provide a longer service life.
  • Designed for easy installation. Module use of glass fibre media which is a mini pleat type.

Specifications

Size and performance data
Nominal size W x H x D (in)Actual size W x H x D (mm)Efficiency (EN1822)Air flow / initial resistance (CMH / Pa)
24 x 24 x 6600 x 600 x 152H13600 / 110
36 x 24 x 6900 x 600 x 152H13960 / 110
48 x 24 x 61210 x 600 x 152H131200 / 110
24 x 24 x 6600 x 600 x 152H14600 / 125
36 x 24 x 6900 x 600 x 152H14960 / 125
48 x 24 x 61210 x 600 x 152H141200 / 125
24 x 24 x 6600 x 600 x 152U15600 / 145
36 x 24 x 6900 x 600 x 152U15960 / 145
48 x 24 x 61210 x 600 x 152U151200 / 145
  • Actual sizes are measured without gasket.
View the original specification image

Diagram

Disposable Ceiling Module diagram
V-Bank MiniPleat Filter
  • Extended media surface creates lower resistance to higher air flow which saves energy consumption.
  • Large media area provides the filters with a longer serving life and higher dust holding capacity.

Specifications

Size and performance data
Nominal size W x H x D (in)Actual size W x H x D (mm)Efficiency (EN1822)Air flow / initial resistance (CMH / Pa)
24 x 12 x 12594 x 289 x 292E101700 / 220
24 x 20 x 12594 x 492 x 292E102839 / 220
24 x 24 x 12594 x 594 x 292E103400 / 220
24 x 12 x 12594 x 289 x 292H131700 / 280
24 x 20 x 12594 x 492 x 292H132839 / 280
24 x 24 x 12594 x 594 x 292H133400 / 280
24 x 12 x 12594 x 289 x 292U151700 / 310
24 x 20 x 12594 x 492 x 292U152839 / 310
24 x 24 x 12594 x 594 x 292U153400 / 310
View the original specification image

Diagram

V-Bank MiniPleat Filter diagram
V-Bank Mini Pleat Filter (Box Type)
  • Extended media surface creates lower resistance to higher air flow which saves energy consumption.
  • Large media area provides the filters with a longer serving life and higher dust holding capacity.

Specifications

Size and performance data
Nominal size W x H x D (in)Actual size W x H x D (mm)Efficiency (EN1822)Air flow / initial resistance (CMH / Pa)
12 x 24 x 12305 x 610 x 292E101500 / 210
24 x 24 x 12610 x 610 x 292E103000 / 210
12 x 24 x 12305 x 610 x 292H131500 / 270
24 x 24 x 12610 x 610 x 292H133000 / 270
12 x 24 x 12305 x 610 x 292U151500 / 320
24 x 24 x 12610 x 610 x 292U153000 / 320
  • Actual sizes are measured without gasket.
View the original specification image

Diagram

V-Bank Mini Pleat Filter (Box Type) diagram
Aluminium Separator Filter (High Air Capacity)
  • The media pack consists of pleated micro glass paper media and corrugated aluminium separator which is sealed inside the metal frame forming a totally rigid filter assembly.
  • Polyurethane sealant applies throughout all over the filter to prevent any possible leakage.

Specifications

Size and performance data
Nominal size W x H x D (in)Actual size W x H x D (mm)Efficiency (EN1822)Air flow / initial resistance (CMH / Pa)
12 x 24 x 6305 x 610 x 150E10850 / 150
24 x 24 x 6610 x 610 x 150E101700 / 150
12 x 24 x 12305 x 610 x 292E101700 / 150
24 x 24 x 12610 x 610 x 292E103400 / 150
12 x 24 x 6305 x 610 x 150H13850 / 350
24 x 24 x 6610 x 610 x 150H131700 / 350
12 x 24 x 12305 x 610 x 292H131700 / 350
24 x 24 x 12610 x 610 x 292H133400 / 350
12 x 24 x 6305 x 610 x 150U15850 / 380
24 x 24 x 6610 x 610 x 150U151700 / 380
12 x 24 x 12305 x 610 x 292U151700 / 380
24 x 24 x 12610 x 610 x 292U153400 / 380
  • Actual sizes are measured without gasket. Data based on no header.
View the original specification image

Diagram

Aluminium Separator Filter (High Air Capacity) diagram
Aluminium Separator Filter (Std Air Capacity)
  • The media pack consists of pleated micro glass paper media and corrugated aluminium separator which is sealed inside the metal frame forming a totally rigid filter assembly.
  • Polyurethane sealant applies throughout all over the filter to prevent any possible leakage.

Specifications

Size and performance data
Nominal size W x H x D (in)Actual size W x H x D (mm)Efficiency (EN1822)Air flow / initial resistance (CMH / Pa)
12 x 24 x 6305 x 610 x 150E10425 / 98
24 x 24 x 6610 x 610 x 150E10850 / 98
12 x 24 x 12305 x 610 x 292E10850 / 98
24 x 24 x 12610 x 610 x 292E101700 / 98
12 x 24 x 6305 x 610 x 150H13425 / 249
24 x 24 x 6610 x 610 x 150H13850 / 249
12 x 24 x 12305 x 610 x 292H13850 / 249
24 x 24 x 12610 x 610 x 292H131700 / 249
12 x 24 x 6305 x 610 x 150U15425 / 280
24 x 24 x 6610 x 610 x 150U15850 / 280
12 x 24 x 12305 x 610 x 292U15850 / 280
24 x 24 x 12610 x 610 x 292U151700 / 280
  • Actual sizes are measured without gasket. Data based on no header.
View the original specification image

Diagram

Aluminium Separator Filter (Std Air Capacity) diagram

HEPA / ULPA Filters: common questions

What are HEPA and ULPA filters?

HEPA and ULPA filters are the final, high-efficiency stage of cleanroom filtration. HEPA is typically rated at least 99.97% at 0.3 µm and ULPA at least 99.999% at 0.12 µm, and the grade you fit sets the class your cleanroom can reach.

Which hepa & ulpa filters models does Vicfil supply?

Vicfil supplies 8 models: MiniPleat Filter, Permanent Ceiling Module, Permanent Ceiling Module RSC Type, Disposable Ceiling Module, V-Bank MiniPleat Filter, V-Bank Mini Pleat Filter (Box Type), Aluminium Separator Filter (High Air Capacity), Aluminium Separator Filter (Std Air Capacity).

Where is it used?

Cleanroom ceilings, fan filter units, air handling units and clean equipment in semiconductor, pharmaceutical, hospital and laboratory facilities.

Can it be customised?

Yes. Vicfil can customise the size, layout and options to your room and process. Send your requirements with the enquiry form.

Is there a datasheet I can download?

Yes. 3 PDF datasheets are available to download from this page: HEPA Minipleat Filter, Permanent Ceiling Module H14, Disposable Ceiling Module.

How do I get a quotation?

Add the models you need to your enquiry list and send the enquiry form with your quantities. You can also WhatsApp +6012 272 3963 or email sales@vicfil.com.

Enquiry list · 0Add any model to ask for a quotation.