Industrial Air Filters in Malaysia

Industrial air filters remove dust, fine particles and gases from the air that enters a building or a process. Vicfil supplies every filter stage in Malaysia: primary, secondary, HEPA/ULPA, chemical and mesh filters.

5products
23models
Vicfil HEPA MiniPleat air filter
The range

Industrial Air Filters: every product and model

Filters for every stage of air handling, used in semiconductor plants, pharmaceutical factories, hospitals, laboratories, airports, commercial buildings and food production. Open any model for its details, or add it to your enquiry list.

Primary Air Filters

Pre-filters that catch coarse dust at the intake and protect finer stages.

  • Washable Panel Filter

    Filters are economical and offers an effective solution to industrial air filtration.

    Specifications · PDF
  • Extended Surface Pleated Filter (Standard)

    The pleated filter uses synthetic media and is bonded to a wire mesh on the air leaving side and enclosed into the beverage board. There are three types of thickness, 1″, 2″ and 4″ with G4 (87-92%) efficiency.

    Specifications · PDF
  • Extended Surface Pleated Filter (Premium)

    The pleated filter uses synthetic media and is bonded to a wire mesh on the air leaving side and enclosed into the beverage board. There is three kinds of thickness, 1″, 2″ and 4″ with G4 (87-92%) efficiency.

    Specifications · PDF
  • High-Temperature Media Filter

    These filters have a heavy dust holding capacity and longer service life.

    Specifications
  • Washable Media Roll

    Media consisting of 100% polyester bonded fibres are formed into an interlocking pattern that traps dust and lint. This minimises the face surface loading.

    Specifications

Secondary Air Filters

Medium and fine filters inside the air handling unit.

  • Extended Surface Pocket Filter

    Synthetic pocket filters are constructed with synthetic media and assembled in galvanised steel or aluminium extrusion frame. Pocket filter offers high-efficiency filtration while maintaining a low resistance to airflow.

    Specifications
  • V-Bank MiniPleat Filter

    Extended media surface creates lower resistance to higher airflow which saves energy consumption. Large media area provides the filters with a longer serving life and higher dust holding capacity.

    Specifications
  • Rigid Pleated Filter

    Rigid box filter is a rigid, extended surface medium to high-efficiency filter. Galvanised steel frame, diagonal support bracing, moisture resistant media contour stabilizers and metal media support grid enhance the durability of the filter.

    Specifications
  • Aluminium Separator Filter

    The media pack consists of pleated micro-glass paper media and corrugated aluminium separators. It is sealed inside the metal frame forming a totally rigid filter assembly. Polyurethane sealant is applied to prevent any possible leakage.

    Specifications
  • MiniPleat Filter (Metal Frame Type)

    Medium efficiency filters are built in the metal frame with 4″ depth to save space.

    Specifications
  • MiniPleat Filter (Beverage Board Type)

    Medium efficiency filters are built in the beverage board frame with 4″ depth to save space.

    Specifications

HEPA / ULPA Filters

Final-stage high-efficiency filters and ceiling modules that set your cleanroom class.

  • MiniPleat Filter

    Filter uses a mini pleat glass fibre media with efficiencies from H13 to U15. The extended media surface combined with precisely controlled bead separator pleating creates low resistance to air flow and save energy consumption.

    Specifications · PDF
  • Permanent Ceiling Module

    Complete unit designed with a low pressure drop to save energy consumption and provide a longer service life. Designed for easy installation. Filter use glass fibre media which is a mini pleat type and aluminium separator type.

    Specifications · PDF
  • Permanent Ceiling Module RSC Type

    Complete unit designed with a low pressure drop to save energy consumption and provide a longer service life. Designed for easy installation. Filter use glass fibre media which is a mini pleat type. Casing are designed with a permanent knife edge for gasket and a Gel Seal type filter.

    Specifications
  • Disposable Ceiling Module

    Complete unit designed with a low pressure drop to save energy consumption and provide a longer service life. Designed for easy installation. Module use of glass fibre media which is a mini pleat type.

    Specifications · PDF
  • V-Bank MiniPleat Filter

    Extended media surface creates lower resistance to higher air flow which saves energy consumption. Large media area provides the filters with a longer serving life and higher dust holding capacity.

    Specifications
  • V-Bank Mini Pleat Filter (Box Type)

    Extended media surface creates lower resistance to higher air flow which saves energy consumption. Large media area provides the filters with a longer serving life and higher dust holding capacity.

    Specifications
  • Aluminium Separator Filter (High Air Capacity)

    The media pack consists of pleated micro glass paper media and corrugated aluminium separator which is sealed inside the metal frame forming a totally rigid filter assembly. Polyurethane sealant applies throughout all over the filter to prevent any possible leakage.

    Specifications
  • Aluminium Separator Filter (Std Air Capacity)

    The media pack consists of pleated micro glass paper media and corrugated aluminium separator which is sealed inside the metal frame forming a totally rigid filter assembly. Polyurethane sealant applies throughout all over the filter to prevent any possible leakage.

    Specifications

Chemical Filters

Carbon and chemical media for gases, odours and airborne molecular contamination.

  • Chemical Carbon Pleated Filter

    Constructed with a beverage board and pleated media to provide maximum effective area. Carbon pleated filters remove a wide range of odours and common indoor air pollutants.

    Specifications · PDF
  • Chemical Rigid Pleated Filter

    The gas-phase rigid pleated filter ensures a higher effective active area per kg of media, resulting in a high spontaneity of reactions Gas-phase rigid pleated filters remove a wide range of odours and common indoor air pollutants.

    Specifications · PDF
  • Chemical V-Bank MiniPleat Filter

    Gas-phase V bank filter ensures a higher effective active area per kg of media, resulting in high spontaneity of reactions. Gas-phase V bank filters remove a wide range of odours and common indoor air pollutants.

    Specifications

Mesh Filters

Washable metal mesh and grease filters.

1 model
  • Metal Mesh / Grease Filter

    These metal mesh filter is applicable for commercial building, industrial, and other general purposes.

    Specifications · PDF

What are industrial air filters?

Industrial air filters remove dust, fine particles and gases from the air that enters a building or a process. Vicfil supplies every filter stage in Malaysia: primary, secondary, HEPA/ULPA, chemical and mesh filters.

Clean air is built in stages. A primary filter catches coarse dust at the intake, a secondary filter removes finer particles inside the air handling unit, and a HEPA or ULPA filter at the end sets the cleanliness class of the room. Each stage protects the next one, so the final filter lasts longer.

Chemical filters deal with what particle filters cannot: gases, odours and airborne molecular contamination. Mesh filters are washable metal filters for grease and coarse dust.

How to choose

  • Start from the cleanliness you needThe room class or the process decides the final filter. Work back from there to the stages before it.
  • Match the frame and sizeTell us the housing or AHU model, or the size of the filter you use now, and we will match it.
  • Check the airflowA filter has to pass the airflow your system needs. Give us the airflow and we will size the filter to it.
  • Plan the replacementsPrimary filters are changed most often and final filters least. We can supply to your maintenance schedule.
Where it is used
Semiconductor plants, pharmaceutical factories, hospitals, laboratories, airports, commercial buildings and food production.
Range
Primary Air Filters, Secondary Air Filters, HEPA / ULPA Filters, Chemical Filters, Mesh Filters
Supplied by
Vicfil Sdn. Bhd., Puchong, Selangor. Delivery across Malaysia.

Industrial Air Filters: common questions

What are the stages of air filtration?

There are three main stages. Primary filters catch coarse dust at the intake, secondary filters remove finer particles in the air handling unit, and HEPA or ULPA filters are the final stage that sets the cleanroom class. Chemical filters are added where gases or odours must be removed.

What is the difference between a HEPA and a ULPA filter?

Both are final-stage filters. A ULPA filter captures a higher share of very small particles than a HEPA filter and is used for the cleanest rooms, such as semiconductor processes. HEPA is the usual choice for most cleanrooms, hospitals and pharmaceutical areas.

Can Vicfil match the filters I use now?

Yes. Send the size, frame type and efficiency of your current filter, or the model of your air handling unit, and Vicfil will quote a matching filter.

How do I get a quotation?

Add the models you need to your enquiry list and send the enquiry form with your quantities. You can also WhatsApp +6012 272 3963 or email sales@vicfil.com.

Enquiry list · 0Add any model to ask for a quotation.