Secondary Air Filters in Malaysia
A secondary air filter is the medium to fine efficiency stage inside an air handling unit. It removes the finer dust that passes the pre-filter and protects the final HEPA or ULPA filters.

Secondary Air Filters range
Medium and fine filters inside the air handling unit. Open any model for its details, or add it to your enquiry list.
Extended Surface Pocket Filter
Synthetic pocket filters are constructed with synthetic media and assembled in galvanised steel or aluminium extrusion frame. Pocket filter offers high-efficiency filtration while maintaining a low resistance to airflow.
SpecificationsV-Bank MiniPleat Filter
Extended media surface creates lower resistance to higher airflow which saves energy consumption. Large media area provides the filters with a longer serving life and higher dust holding capacity.
SpecificationsRigid Pleated Filter
Rigid box filter is a rigid, extended surface medium to high-efficiency filter. Galvanised steel frame, diagonal support bracing, moisture resistant media contour stabilizers and metal media support grid enhance the durability of the filter.
SpecificationsAluminium Separator Filter
The media pack consists of pleated micro-glass paper media and corrugated aluminium separators. It is sealed inside the metal frame forming a totally rigid filter assembly. Polyurethane sealant is applied to prevent any possible leakage.
SpecificationsMiniPleat Filter (Metal Frame Type)
Medium efficiency filters are built in the metal frame with 4″ depth to save space.
SpecificationsMiniPleat Filter (Beverage Board Type)
Medium efficiency filters are built in the beverage board frame with 4″ depth to save space.
Specifications
What is a secondary air filter?
A secondary air filter is the medium to fine efficiency stage inside an air handling unit. It removes the finer dust that passes the pre-filter and protects the final HEPA or ULPA filters.
- Where it is used
- Inside air handling units serving cleanrooms, hospitals, laboratories and commercial buildings, between the pre-filter and the final filter.
- Range
- Extended Surface Pocket Filter, V-Bank MiniPleat Filter, Rigid Pleated Filter, Aluminium Separator Filter, MiniPleat Filter (Metal Frame Type), MiniPleat Filter (Beverage Board Type)
- Supplied by
- Vicfil Sdn. Bhd., Puchong, Selangor. Delivery across Malaysia.
Secondary Air Filters specifications and details
Extended Surface Pocket Filter
- Synthetic pocket filters are constructed with synthetic media and assembled in galvanised steel or aluminium extrusion frame.
- Pocket filter offers high-efficiency filtration while maintaining a low resistance to airflow.
Specifications
| Nominal size W x H x D (in) | Actual size W x H x D (mm) | Number of pockets | F8: air flow / initial resistance (CMH / Pa) | F7: air flow / initial resistance (CMH / Pa) | F6: air flow / initial resistance (CMH / Pa) |
|---|---|---|---|---|---|
| 12 x 24 x 36 | 287 x 592 x 914 | 4 | 1700 / 66 | 1700 / 59 | 1700 / 51 |
| 20 x 24 x 36 | 490 x 592 x 914 | 6 | 2839 / 66 | 2839 / 59 | 2839 / 51 |
| 24 x 24 x 36 | 592 x 592 x 914 | 8 | 3400 / 66 | 3400 / 59 | 3400 / 51 |
| 12 x 24 x 30 | 287 x 592 x 762 | 4 | 1700 / 80 | 1700 / 67 | 1700 / 55 |
| 20 x 24 x 30 | 490 x 592 x 762 | 6 | 2839 / 80 | 2839 / 67 | 2839 / 55 |
| 24 x 24 x 30 | 592 x 592 x 762 | 8 | 3400 / 80 | 3400 / 67 | 3400 / 55 |
| 12 x 24 x 21 | 287 x 592 x 534 | 4 | 1700 / 112 | 1700 / 87 | 1700 / 63 |
| 20 x 24 x 21 | 490 x 592 x 534 | 6 | 2839 / 112 | 2839 / 87 | 2839 / 63 |
| 24 x 24 x 21 | 592 x 592 x 534 | 8 | 3400 / 112 | 3400 / 87 | 3400 / 63 |
| 12 x 24 x 15 | 287 x 592 x 381 | 4 | 1700 / 144 | 1700 / 104 | 1700 / 65 |
| 20 x 24 x 15 | 490 x 592 x 381 | 6 | 2839 / 144 | 2839 / 104 | 2839 / 65 |
| 24 x 24 x 15 | 592 x 592 x 381 | 8 | 3400 / 144 | 3400 / 104 | 3400 / 65 |
Questions and answers
What is a secondary air filter in industrial HVAC systems?
A secondary air filter is used after a primary filter to further capture smaller particles, improving indoor air quality and protecting sensitive equipment in industrial settings.
What’s the difference between primary and secondary air filters?
Primary filters capture larger particles like dust and debris, while secondary filters trap finer particles such as pollen, mold spores, and microscopic pollutants.
Where are secondary air filters used in industrial applications?
They are commonly used in cleanrooms, pharmaceutical production, food processing plants, and other environments where high-efficiency air purification is required.
How often should I replace secondary air filters in an industrial system?
Replacement depends on usage and environment but typically ranges from every 3 to 6 months. High-dust or sterile environments may require more frequent changes
What efficiency ratings are available for Vicfil secondary filters?
Vicfil offers a range of efficiency options to match your needs—from MERV 8 to MERV 14, and equivalent EU grades.
V-Bank MiniPleat Filter
- Extended media surface creates lower resistance to higher airflow which saves energy consumption.
- Large media area provides the filters with a longer serving life and higher dust holding capacity.
Specifications
| Nominal size W x H x D (in) | Actual size W x H x D (mm) | Efficiency (EN779) | Air flow / initial resistance (CMH / Pa) |
|---|---|---|---|
| 24 x 12 x 12 | 594 x 289 x 292 | F9 | 1700 / 140 |
| 24 x 20 x 12 | 594 x 492 x 292 | F9 | 2839 / 140 |
| 24 x 24 x 12 | 594 x 594 x 292 | F9 | 3400 / 140 |
| 24 x 12 x 12 | 594 x 289 x 292 | F8 | 1700 / 125 |
| 24 x 20 x 12 | 594 x 492 x 292 | F8 | 2839 / 125 |
| 24 x 24 x 12 | 594 x 594 x 292 | F8 | 3400 / 125 |
| 24 x 12 x 12 | 594 x 289 x 292 | F7 | 1700 / 110 |
| 24 x 20 x 12 | 594 x 492 x 292 | F7 | 2839 / 110 |
| 24 x 24 x 12 | 594 x 594 x 292 | F7 | 3400 / 110 |
| 24 x 12 x 12 | 594 x 289 x 292 | F6 | 1700 / 95 |
| 24 x 20 x 12 | 594 x 492 x 292 | F6 | 2839 / 95 |
| 24 x 24 x 12 | 594 x 594 x 292 | F6 | 3400 / 95 |
Diagram
| Nominal size W x H x D (in) | Actual size W x H x D (mm) | Efficiency (EN779) | Air flow / initial resistance (CMH / Pa) |
|---|---|---|---|
| 24 x 12 x 12 | 594 x 289 x 292 | F9 | 1700 / 140 |
| 24 x 20 x 12 | 594 x 492 x 292 | F9 | 2839 / 140 |
| 24 x 24 x 12 | 594 x 594 x 292 | F9 | 3400 / 140 |
| 24 x 12 x 12 | 594 x 289 x 292 | F8 | 1700 / 125 |
| 24 x 20 x 12 | 594 x 492 x 292 | F8 | 2839 / 125 |
| 24 x 24 x 12 | 594 x 594 x 292 | F8 | 3400 / 125 |
| 24 x 12 x 12 | 594 x 289 x 292 | F7 | 1700 / 110 |
| 24 x 20 x 12 | 594 x 492 x 292 | F7 | 2839 / 110 |
| 24 x 24 x 12 | 594 x 594 x 292 | F7 | 3400 / 110 |
| 24 x 12 x 12 | 594 x 289 x 292 | F6 | 1700 / 95 |
| 24 x 20 x 12 | 594 x 492 x 292 | F6 | 2839 / 95 |
| 24 x 24 x 12 | 594 x 594 x 292 | F6 | 3400 / 95 |
Rigid Pleated Filter
- Rigid box filter is a rigid, extended surface medium to high-efficiency filter.
- Galvanised steel frame, diagonal support bracing, moisture resistant media contour stabilizers and metal media support grid enhance the durability of the filter.
Specifications
| Nominal size W x H x D (in) | Actual size W x H x D (mm) | Efficiency (EN779) | Air flow / initial resistance (CMH / Pa) |
|---|---|---|---|
| 12 x 24 x 12 | 289 x 594 x 292 | F8 | 1700 / 125 |
| 20 x 20 x 12 | 492 x 492 x 292 | F8 | 2380 / 125 |
| 20 x 24 x 12 | 492 x 594 x 292 | F8 | 2839 / 125 |
| 24 x 24 x 12 | 594 x 594 x 292 | F8 | 3400 / 125 |
| 12 x 24 x 12 | 289 x 594 x 292 | F7 | 1700 / 105 |
| 20 x 20 x 12 | 492 x 492 x 292 | F7 | 2380 / 105 |
| 20 x 24 x 12 | 492 x 594 x 292 | F7 | 2839 / 105 |
| 24 x 24 x 12 | 594 x 594 x 292 | F7 | 3400 / 105 |
| 12 x 24 x 12 | 289 x 594 x 292 | F6 | 1700 / 70 |
| 20 x 20 x 12 | 492 x 492 x 292 | F6 | 2380 / 70 |
| 20 x 24 x 12 | 492 x 594 x 292 | F6 | 2839 / 70 |
| 24 x 24 x 12 | 594 x 594 x 292 | F6 | 3400 / 70 |
- Data based on no header.
Aluminium Separator Filter
- The media pack consists of pleated micro-glass paper media and corrugated aluminium separators. It is sealed inside the metal frame forming a totally rigid filter assembly.
- Polyurethane sealant is applied to prevent any possible leakage.
Specifications
| Nominal size W x H x D (in) | Actual size W x H x D (mm) | Efficiency (EN779) | Air flow / initial resistance (CMH / Pa) |
|---|---|---|---|
| 12 x 24 x 6 | 289 x 594 x 150 | F8 | 850 / 108 |
| 20 x 24 x 6 | 492 x 594 x 150 | F8 | 1420 / 108 |
| 24 x 24 x 6 | 594 x 594 x 150 | F8 | 1700 / 108 |
| 12 x 24 x 6 | 289 x 594 x 150 | F7 | 850 / 78 |
| 20 x 24 x 6 | 492 x 594 x 150 | F7 | 1420 / 78 |
| 24 x 24 x 6 | 594 x 594 x 150 | F7 | 1700 / 78 |
| 12 x 24 x 6 | 289 x 594 x 150 | F6 | 850 / 59 |
| 20 x 24 x 6 | 492 x 594 x 150 | F6 | 1420 / 59 |
| 24 x 24 x 6 | 594 x 594 x 150 | F6 | 1700 / 59 |
| 12 x 24 x 12 | 289 x 594 x 292 | F8 | 1700 / 145 |
| 20 x 24 x 12 | 492 x 594 x 292 | F8 | 2839 / 145 |
| 24 x 24 x 12 | 594 x 594 x 292 | F8 | 3400 / 145 |
| 12 x 24 x 12 | 289 x 594 x 292 | F7 | 1700 / 127 |
| 20 x 24 x 12 | 492 x 594 x 292 | F7 | 2839 / 127 |
| 24 x 24 x 12 | 594 x 594 x 292 | F7 | 3400 / 127 |
| 12 x 24 x 12 | 289 x 594 x 292 | F6 | 1700 / 108 |
| 20 x 24 x 12 | 492 x 594 x 292 | F6 | 2839 / 108 |
| 24 x 24 x 12 | 594 x 594 x 292 | F6 | 3400 / 108 |
- Data based on no header.
MiniPleat Filter (Metal Frame Type)
Medium efficiency filters are built in the metal frame with 4″ depth to save space.
Specifications
| Nominal size W x H x D (in) | Actual size W x H x D (mm) | Efficiency (EN779) | Air flow / initial resistance (CMH / Pa) |
|---|---|---|---|
| 12 x 24 x 4 | 289 x 594 x 95 | F8 | 1700 / 170 |
| 20 x 24 x 4 | 492 x 594 x 95 | F8 | 2839 / 170 |
| 24 x 24 x 4 | 594 x 594 x 95 | F8 | 3400 / 170 |
| 12 x 24 x 4 | 289 x 594 x 95 | F7 | 1700 / 150 |
| 20 x 24 x 4 | 492 x 594 x 95 | F7 | 2839 / 150 |
| 24 x 24 x 4 | 594 x 594 x 95 | F7 | 3400 / 150 |
| 12 x 24 x 4 | 289 x 594 x 95 | F6 | 1700 / 105 |
| 20 x 24 x 4 | 492 x 594 x 95 | F6 | 2839 / 105 |
| 24 x 24 x 4 | 594 x 594 x 95 | F6 | 3400 / 105 |
MiniPleat Filter (Beverage Board Type)
Medium efficiency filters are built in the beverage board frame with 4″ depth to save space.
Specifications
| Nominal size W x H x D (in) | Actual size W x H x D (mm) | Efficiency (EN779) | Air flow / initial resistance (CMH / Pa) |
|---|---|---|---|
| 12 x 24 x 4 | 289 x 594 x 95 | F8 | 1700 / 170 |
| 20 x 24 x 4 | 492 x 594 x 95 | F8 | 2839 / 170 |
| 24 x 24 x 4 | 594 x 594 x 95 | F8 | 3400 / 170 |
| 12 x 24 x 4 | 289 x 594 x 95 | F7 | 1700 / 150 |
| 20 x 24 x 4 | 492 x 594 x 95 | F7 | 2839 / 150 |
| 24 x 24 x 4 | 594 x 594 x 95 | F7 | 3400 / 150 |
| 12 x 24 x 4 | 289 x 594 x 95 | F6 | 1700 / 105 |
| 20 x 24 x 4 | 492 x 594 x 95 | F6 | 2839 / 105 |
| 24 x 24 x 4 | 594 x 594 x 95 | F6 | 3400 / 105 |
Secondary Air Filters: common questions
What is a secondary air filter?
A secondary air filter is the medium to fine efficiency stage inside an air handling unit. It removes the finer dust that passes the pre-filter and protects the final HEPA or ULPA filters.
Which secondary air filters models does Vicfil supply?
Vicfil supplies 6 models: Extended Surface Pocket Filter, V-Bank MiniPleat Filter, Rigid Pleated Filter, Aluminium Separator Filter, MiniPleat Filter (Metal Frame Type), MiniPleat Filter (Beverage Board Type).
Where is it used?
Inside air handling units serving cleanrooms, hospitals, laboratories and commercial buildings, between the pre-filter and the final filter.
Can it be customised?
Yes. Vicfil can customise the size, layout and options to your room and process. Send your requirements with the enquiry form.
How do I get a quotation?
Add the models you need to your enquiry list and send the enquiry form with your quantities. You can also WhatsApp +6012 272 3963 or email sales@vicfil.com.